• Connectivity

    Maximize your investments.

    MUSE v9 is designed to bridge the communication gap between vendors, modalities, clinics, hospitals, care areas and your enterprise. That means you'll be able to maximize the clinical benefits MUSE provides and bridge your diagnostic cardiology investments.

    MUSE eDoc Connect provides an open and direct multi-modality, multi-vendor solution.
    • Easy integration of non-GE technologies
    • Direct connectivity to receive and store reports from other network-connected devices such as stress testing equipment, electrocardiographs, wearables, pulmonary function equipment and more
    • Patient information and clinical resulsts available in a single view
    • Built-in interface removes the burden of IT maintaining additional interfaces

  • MUSE DICOM Connect

    MUSE DICOM Connect provides the direct link between the resting ECG data acquisition and DICOM protocol based systems which could include EMRs, PACS and RIS.
    • MUSE receives DICOMTM modality worklists and converts them to complete an efficient resting ECG workflow for the cardiology department
    • Critical information can be shared with the imaging/ radiology workstation to help increase the speed and accuracy of cardiac diagnosis
    • Maintain a diagnostic ECG expert system to edit, confirm and route ECGs without compromising workflow
    • Send DICOM-formatted resting ECGs to a PACS or VNA (vendor neutral archive) on demand

  • Security and Auditing

    Enhanced System Security and Privacy

    In today's unpredictable and complex environment, healthcare providers must ensure system integrity and regulatory compliance.

    MUSE A/D Connect
    • Provides integration with active directory solutions for a more simplified and secure login process
    • Enables each authorized user to have a single sign on at the enterprise level
    • Establishes centralized activation/deactivation process, which can be configured to use LDAP groups for user accounts, or use existing functionality to create MUSE users
    • Eliminates the need for administrators to maintain separate MUSE system user names and passwords
    • Saves time and simplifies IT security, user account management,and hospital network administration

    Audit and Data Logging
    The enhanced audit and data logging tools available in the MUSE system is essential for compliance and quality improvements.
    • Comprehensive audit component tracks by whom and when any patient record is searched, accessed, and viewed, supporting the facilities ability to satisfy the HIPAA (Healthcare Insurance Portability and Accountability Act) requirement
    • To maintain patient privacy, data access logs record details (e.g. user, workstation, time stamp) any time a test was opened or printed
    • Includes accessing and exporting error logs to third party tools, enabling service personnel to better understand the problems and/or verifying user functionality

  • MUSE ECG Insights

    MUSE™ ECG Insights is part of GE Healthcare’s Applied Intelligence portfolio of analytics solutions. It unleashes the power of the MUSE data to solve your most significant ECG process challenges. MUSE ECG Insights uses data collected by the system to provide administrators and clinical leaders visibility to information that empowers them to optimize ECG processes, workflow and asset utilization which can lead to higher quality patient throughput and financial outcomes.

    With the ability to process near real-time data, MUSE ECG Insights displays information in easy to understand dashboard formats. Users can access aggregated, roll-up dashboards and drill into underlying data to better understand challenges or best practices to optimize cardiology service line.

    Key performance dashboards include:

    • Executive Summary providing views into the complete ECG process from Order to final physician over read.
    • ECG Quality helping to better understand quality issues starting at test acquisition
    • Duplicate ECGs identifies root cause of repeat and rejected tests and leading to unbilled exams without Orders
    • Workflow Efficiency visualize operational bottlenecks from aggregated data with a broad set of operational metrics
    • Transmit Time Efficiency view locations to identify cause of delayed study acquisition leading to extended physician over read times and lost billing opportunity
    • Asset Utilization helps detect underutilized ECG devices enabling cost savings through potential redeployment to areas with higher utilization.
    ECG quality and workflow optimization tools.jpg
  • Enterprise Workflow

    The MUSE platform is designed to scale from stand-alone critical access hospitals to enterprise solutions implemented by major healthcare systems worldwide.

    Regardless of the solution, standalone or enterprise. MUSE can help you seamlessly connect data to you physicians. Having a comprehensive, flexible, and easily accessible system gives the ability to correlate care when patients are seen at multiple sites.

    Many healthcare systems have merged independent MUSE systems into a single solution to help reduce hardware footprint, HL7 configuration and software licensing fees, while providing expanded capabilities while reducing operational expenses.

    Pre-hospital and STEMI workflow
    Every moment counts when a person is having a heart attack. MUSE can integrate with other vebdor prehospital 12 lead ECG systms so that treatment decisions can be made quickly and departments, such as the Cath Lab can begin to prepare for patient arrival and treatment. See how MUSE helps save time with Prehospital ECG

    Advanced barcode workflow
    MUSE v9 along with enhanced barcode capabilities of the MAC5500 work together to help improve efficiency across the enterprise. Quickly attach patient information to the test even before the order is complete. This solution is designed to help avoid costly misdiagnoses, automate processes for clinicians, and streamline workflow supporting improved quality of care and reduced cost for the hospital.

    Click graphic below to see the MAC 5500 HD and MUSE systems working together to improve ECG workflow.

    product-product-categories-diagnostic-ecg-cardio data-muse v9-muse v9 workflow new.jpg

    Enterprise workflow
    As your enterprise expands testing moves to outpatient and offices. The MUSE platform is designed to help you seamlessly connect multiple clinics and offices enabling data sharing across your enterprise whether for ECG, Stress, Holter or other diagnostic cardiac testing.

    Primary Care Workflow
    As the care path expands for your patients so does the need to distribute results. MUSE v9 enables users to route reports to additional physicians including Attending, Admitting, Primary Care Physicians and Family Practitioners.

  • Clinical Expertise

    The MUSETM system is built on decades of research invested into the development of ECG analysis tools. Quality tools, validated against clinically correlated databases for accuracy and supported with over 150 scientific references. MUSETM v9 builds on its heritage of storing and analyzing clinically rich cardiac data and allows it to be easily accessed and transferred automatically. It's the best of both worlds, so smart hospitals can keep making smart decisions.

    Physician editing tools: Providing an array of easy- to-use report review tools to help you facilitate better patient care. Including: electronic calipers, magnification and statement insertion or free text editing
    Serial Comparison: MUSE stores electrocardiograms with physician-edited interpretations and works in conjunction with the MarquetteTM 12SLTM Serial Comparison program, allowing accurate and expedient assessment of a patient's ECG data


    Pacemaker Annotation: Current pacemakers are difficult to detect on the standard ECG. Pacemaker detection in the MACTM 5500 HD Resting ECG system, with annotation in the MUSE system, detects pacemaker pulses more accurately reducing the risk of treatment contradicted for paced patients. A dedicated pace annotation channel helps reduce the need to identify pacer pulses within the ECG signal, supporting efficient diagnosis when moments can make a difference. It even detects bi-ventricular pacemakers

Support

JB01567IN

WIPRO GE HEALTHCARE PVT LTD
No. 4, Kadugodi Industrial Area,
Bangalore 560067,
Karnataka, India
CIN: U33111KA1990PTC01606
Grievance Officer: Nestor J. Rivera
Chief Privacy Counsel/Officer, GE HealthCare